Coluna/Columna
http://www.coluna.periodikos.com.br/article/doi/10.1590/S1808-185120242302288420
Coluna/Columna
Artigo Original Deformidade

CHANGES OF VERTEBRAL SEGMENT AND FORAMEN WITH ANTERIOR INTERBODY SPACER

ALTERAÇÃO DO SEGMENTO E FORAME VERTEBRAL COM ESPAÇADOR INTERSOMÁTICO ANTERIOR

ALTERACIÓN DEL SEGMENTO VERTEBRAL Y FORAMEN CON ESPACIADOR INTERSOMÁTICO ANTERIOR

Thiago Dantas Matos; Luis Fernando Tirapelli; Alexandre Machado Andrade; Vitor Araujo Gonçalves; Matheus Pippa Defino; Helton Luiz Aparecido Defino

Downloads: 0
Views: 7

Abstract

Objective: To evaluate the influence of intersomatic spacers used in ALIF on segmental lordosis and height of the intervertebral foramen.

Methods: Intersomatic spacers with different heights (17, 18, 20 and 24 mm), length (20, 25 and 30 mm), and angulation (30 and 40 degrees) were introduced in segments L4-L5 and L5-S1 of two adult cadavers according to the ALIF technique. The lordosis of the vertebral segment and the height of the intervertebral foramina were evaluated before and after placement of the different intersomatic spacers.

Results: An increase in segmental lordosis was observed with the placement of spacers in relation to the initial values. No statistical difference was observed between the different intersomatic spacers. The height of the intervertebral foramen increased with the placement of spacers and a statistical difference was observed between the different intersomatic spacers.

Conclusion: Segmental lordosis increased with the placement of spacers compared to the control group. There was no statistical difference between the different heights and angles of the spacers. The height of the intervertebral foramen increased with the introduction of spacers. A statistically significant difference was observed with the increase in height and angle of the spacers. Level of Evidence III; Experimental study.

Keywords

Spinal Fusion; Lordosis; Vertebral foramen.

Resumo

Objetivo: Avaliar a influência dos espaçadores intersomáticos utilizados no ALIF sobre a lordose segmentar e altura do forame intervertebral.

Métodos: Espaçadores intersomáticos com diferentes alturas (17, 18, 20 e 24 mm), comprimento (20, 25 e 30mm), e angulação (30 e 40 graus) foram introduzidos nos segmentos L4-L5 e L5-S1 de dois cadáveres adultos de acordo com a técnica do ALIF. A lordose do segmento vertebral e a altura dos forames intervertebrais foram avaliados antes e após a colocação dos diferentes espaçadores intersomáticos.

Resultados: Foi observado aumento da lordose segmentar com a colocação dos espaçadores em relação aos valores iniciais. Não foi observado diferença estatística entre os diferentes espaçadores intersomáticos. A altura do forame intervertebral aumentou com a colocação dos espaçadores e foi observado diferença estatística entre os diferentes espaçadores intersomáticos.

Conclusão: A lordose segmentar apresentou aumento com a colocação dos espaçadores em relação ao grupo controle. Não se observou diferença estatística entre as diferentes alturas e angulações dos espaçadores. A altura do forame intervertebral aumentou com a introdução dos espaçadores. Observou-se diferença estatística significativa com o aumento da altura e angulação dos espaçadores. Nível de evidência III; Estudo experimental.

Palavras-chave

Fusão Vertebral; Lordose; Forame Vertebral.

Resumen

Objetivo: Evaluar la influencia de los espaciadores intersomáticos utilizados en ALIF sobre la lordosis segmentaria y la altura del agujero intervertebral.

Métodos: Se introdujeron espaciadores intersomáticos con diferentes alturas (17, 18, 20 y 24 mm), ancho (20, 25 y 30 mm) y ángulo (30 y 40 grados) en los segmentos L4-L5 y L5-S1 de dos cadáveres adultos. de acuerdo con la técnica del ALIF. Se evaluó la lordosis del segmento vertebral y la altura del agujero intervertebral antes y después de la colocación de los diferentes espaciadores intersomáticos.

Resultados: Foi observado aumento da lordose segmentar com colocação dos espaçadores em relación aos valores iniciados. Não foi observado diferença estatística entre os diferentes espaciadores intersomáticos. A altura do forame intervertebral aumengou com colocação dos espaciadores e foi observado diferença estatística entre os diferentes espaciadores intersomáticos.

Conclusión: La lordosis segmentaria presentó un aumento con la colocación de espaciadores en relación al grupo control. Não se observou diferença estatística entre as diferentes alturas y angulações dos espaçadores. La altura del agujero intervertebral aumentó con la introducción de espaciadores. Observe las diferencias estadísticas significativas con el aumento de altura y el ángulo de los espaciadores. Nivel de Evidencia III; Estudio experimental.

Palabras clave

Fusión Vertebral; Lordosis; Foramen Vertebral.

Referências

1 Mobbs RJ, Phan K, Malham G, Seex K, Rao PJ. Lumbar interbody fusion: techniques, indications and comparison of interbody fusion options including PLIF, TLIF, MI-TLIF, OLIF/ATP, LLIF and ALIF. J Spine Surg. 2015;1(1):2-18.

2 Uribe JS, Myhre SL, Youssef JA. Preservation or Restoration of Segmental and Regional Spinal Lordosis Using Minimally Invasive Interbody Fusion Techniques in Degenerative Lumbar Conditions: A Literature Review. Spine (Phila Pa 1976). 2016;41 Suppl 8:S50-8.

3 Lovecchio FC, Vaishnav AS, Steinhaus ME, Othman YA, Gang CH, Iyer S, et al. Does inter-body cage lordosis impact actual segmental lordosis achieved in minimally invasive lumbar spine fusion? Neurosurg Focus. 2020;49(3):E17.

4 Phan K, Mobbs RJ. Evolution of Design of Interbody Cages for Anterior Lumbar Interbody Fusion. Orthop Surg. 2016;8(3):270-7.

5 Than KD, Park P, Fu KM, Nguyen S, Wang MY, Chou D, Nunley PD, et al. Clinical and radiographic parameters associated with best versus worst clinical outcomes in minimally invasive spinal deformity surgery. J Neurosurg Spine. 2016;25(1):21-5.

6 Haque RM, Mundis GM Jr, Ahmed Y, El Ahmadieh TY, Wang MY, Mummaneni PV, et al. Comparison of radiographic results after minimally invasive, hybrid, and open surgery for adult spinal deformity: a multicenter study of 184 patients. Neurosurg Focus. 2014;36(5):E13.

7 Wang M, Dalal S, Bagaria VB, McGrady LM, Rao RD. Changes in the lumbar foramen following anterior interbody fusion with tapered or cylindrical cages. Spine J. 2007;7(5):563-9.

8 Derman PB, Ohnmeiss DD, Lauderback A, Guyer RD. Indirect Decompression for the Treatment of Degenerative Lumbar Stenosis. Int J Spine Surg. 2021;15(6):1066-1071.

9 Phan K, Thayaparan GK, Mobbs RJ. Anterior lumbar interbody fusion versus transforaminal lumbar interbody fusion--systematic review and meta-analysis. Br J Neurosurg. 2015;29(5):705-11.

10 Kadam A, Wigner N, Saville P, Arlet V. Overpowering posterior lumbar instrumentation and fusion with hyperlordotic anterior lumbar interbody cages followed by posterior revision: a preliminary feasibility study. J Neurosurg Spine. 2017;27(6):650-660.

11 Lee CH, Chung CK, Jang JS, Kim SM, Chin DK, Lee JK, et al. Effectiveness of deformity-correction surgery for primary degenerative sagittal imbalance: a meta-analysis. J Neurosurg Spine. 2017;27(5):540-551.

12 Saville PA, Kadam AB, Smith HE, Arlet V. Anterior hyperlordotic cages: early experience and radiographic results. J Neurosurg Spine. 2016;25(6):713-719.

13 Melikian R, Yoon ST, Kim JY, Park KY, Yoon C, Hutton W. Sagittal Plane Correction Using the Lateral Transpsoas Approach: A Biomechanical Study on the Effect of Cage Angle and Surgical Technique on Segmental Lordosis. Spine (Phila Pa 1976). 2016;41 (17):E1016-E1021.

14 Hueng DY, Chung TT, Chuang WH, Hsu CP, Chou KN, Lin SC. Biomechanical effects of cage positions and facet fixation on initial stability of the anterior lumbar interbody fusion motion segment. Spine (Phila Pa 1976). 2014;39(13):E770-6.

15 Cinotti G, De Santis P, Nofroni I, Postacchini F. Stenosis of lumbar intervertebral foramen: anatomic study on predisposing factors. Spine (Phila Pa 1976). 2002;27(3):223-9.

16 Mayoux-Benhamou MA, Revel M, Aaron C, Chomette G, Amor B. A morphometric study of the lumbar foramen. Influence of flexion-extension movements and of isolated disc collapse. Surg Radiol Anat. 1989;11(2):97-102.

17 Hasegawa T, An HS, Haughton VM, Nowicki BH. Lumbar foraminal stenosis: critical heights of the intervertebral discs and foramina. A cryomicrotome study in cadavera. J Bone Joint Surg Am. 1995;77(1):32-8..

18 Kapustka B, Kiwic G, Chodakowski P, Miodoński JP, Wysokiński T, Łączyński M, et al. Anterior lumbar interbody fusion (ALIF): biometrical results and own experiences. Neurosurg Rev. 2020;43(2):687-693.

19 Rao PJ, Maharaj MM, Phan K, Lakshan Abeygunasekara M, Mobbs RJ. Indirect foraminal decompression after anterior lumbar interbody fusion: a prospective radiographic study using a new pedicle-to-pedicle technique. Spine J. 2015;15(5):817-24.

20 Schlegel JD, Champine J, Taylor MS, Watson JT, Champine M, Schleusener RL, Savory KM. The role of distraction in improving the space available in the lumbar stenotic canal and foramen. Spine (Phila Pa 1976). 1994;19(18):2041-7.

21 Chen D, Fay LA, Lok J, Yuan P, Edwards WT, Yuan HA. Increasing neuroforaminal volume by anterior interbody distraction in degenerative lumbar spine. Spine (Phila Pa 1976). 1995;20(1):74-9.

22 Kepler CK, Huang RC, Sharma AK, Meredith DS, Metitiri O, Sama AA, Girardi FP, Cammisa FP. Factors influencing segmental lumbar lordosis after lateral transpsoas interbody fusion. Orthop Surg. 2012;4(2):71-5.

23 Barrey C, Darnis A. Current strategies for the restoration of adequate lordosis during lumbar fusion. World J Orthop. 2015;6(1):117-26.
 


Submetido em:
11/07/2024

Aceito em:
12/07/2024

6a97249ea95395487747c785 coluna Articles
Links & Downloads

Coluna/Columna

Share this page
Page Sections