Resumo

Objetivo: avaliar o uso do fixador interno no tratamento das fraturas da coluna toracolombar e relatar as suas complicações. Métodos: trabalho retrospectivo com 110 pacientes operados no Hospital do Trabalhador – Serviço de Ortopedia, acompanhados desde a data da lesão até a sua alta (do hospital ou do final de tratamento). Resultados: ocorreram 17 complicações em 110 pacientes. A complicação mais freqüente foi a quebra de implante, em 13 pacientes, seguida de processo inflamatório superficial sobre a cabeça dos pinos, ocorrido em três pacientes, sendo todos estes indivíduos magros, onde o implante se tornava mais saliente e com infecção em três casos, sendo que em um deles foi necessária cirurgia. Conclusão: a principal indicação da utilização deste sistema são as fraturas instáveis da coluna toracolombar. É um sistema simples, de fácil montagem e versátil, de uso independente do tipo da fratura e com baixos índices de complicações. Não ocorreu nenhum tipo de problema no trans-operatório, como dificuldade na montagem do implante. A técnica seguiu o padrão usual dos sistemas de fixação pediculares. Observou-se que as complicações relacionadas com os implantes ocorreram nas fraturas instáveis que comprometiam duas colunas: anterior e média. Este fato não interferiu com o resultado clínico final.

Palavras-chave

Fraturas da coluna vertebral/cirurgia; Fixadores internos/utilização; Fixação interna de fraturas/efeitos adversos

Abstract

Objective: to evaluate the internal fixation for the treatment of thoracolombar vertebral fractures and to describe their complications. Methods: background analysis of 110 patients operated on at “Hospital do Trabalhador”, followed-up from the injury until their discharge. Results: in the 110 patients it was observed 17 complications as implant break age the most common one, which occurred in thirteen of patients, followed-by skin inflammatory reaction on the pins’ head, and infection on three patients, in which it was necessary to make a surgical intervention in only one of them. Conclusion: the main indication for utilizing this system is the unstable thoracolombar vertebral fractures. It is a simple, easily-set-up and versatile system, which can be used regardless the type of fracture and with low complication rates. Implant failure is more common on fractures in which there is some instability of the anterior and intermediate spine. Fixation break or fatigue does not obligatorily imply in straightness loss, which, in turn, will necessarily affect the final results of the treatment.

Keywords

Spinal fractures/surgery; Internal fixators/utilization; Fracture fixation, interna/adverse effects

Resumen

Objetivo: evaluar el uso de fijador interno en el tratamiento de las fracturas de la columna toracolumbar y relatar sus complicaciones. Métodos: trabajo retrospectivo con 110 casos, operados en el Hospital do Trabalhador – Serviço de Ortopedia, acompañados desde la fecha de la lesión hasta el alta (del hospital o del final del tratamiento). Resultados: en 110 pacientes ocurrieron 17 complicaciones. La complicación mas frecuente fue la quiebra de implante en 13 casos seguido de un proceso inflamatorio superficial sobre la cabeza de los pinos e infección en tres casos, siendo que en uno fue necesario una cirugía. Conclusión: la principal indicación de la utilización de este sistema es en fracturas inestables de la columna toracolumbar. Es un sistema sencillo, de fácil montaje y versátil, de uso independiente del tipo de la fractura y con bajos índices de complicaciones. Se observó que las complicaciones relacionadas con los implantes ocurrieron en las fracturas inestables que comprometían dos columnas: anterior y media. Siendo que ese hecho no interfirió con el resultado clínico final.

Palabras clave

Fracturas espinales/cirugía; Fijadores internos/utilización; Fijación interna de fracturas/efectos adversos